Video Systems - Video Cameras
STAHL LEDCAM 1CCD Digital Video Camera with Integrated LED Light Source
General Specs
Sensor
Camera
Light Source
STAHL Swift 1HD USB
Camera head:
System
Dimensions
Video out terminal
Standard
Features
Delivery contains
Features
Optional accessories
Swift 1HD camera head
STAHL Swift 1 USB
Camera head:
System
Video out terminal
2x Video; 2x S-Video; 1x Y-Pb-Pr (Component); 1x SDI; 1x USB 2.0
Standard
Dimensions
Delivery contains
Video system
Options
Freeze function
Remote camera head
Remote footswitch
Storz Image1 HUB, 3CCD Digital HD Ref: 22201020-104
The IMAGE 1 HUB HD family constitutes the backbone of the KARL STORZ FULL HD Imaging System. With 1,920 x 1,080 resolution and progressive scan, the camera control unit (CCU) guarantees a lag-free image and natural color reproduction. The unique combination of ease-of-use and excellent image quality ensures time-efficiency and maximum patient safety, marking a new milestone in the evolution of endoscopic imaging.
IMAGE 1 offers documentation and printing functions as integrated modules. The CCU’s front and rear USB ports allow for the simultaneous connection of various printers and USB mass storage devices.
All IMAGE 1 Camera Heads, regardless of whether they are FULL HD, standard definition, or designed for video endoscopy, can be used with a single IMAGE 1 HUB CCU.
Image 1 HUB HD Camera Heads:
Storz 22200020-055 Image 1, 3CCD Digital
mage 1HD offers the highest standard ever for endoscopic imaging 1080p60. It acquires and displays surgical images in 16:9 for the widest and most natural aspect ratio possible. The technology uses progressive scanning at 60 frames per second to capture fast-moving objects and produce sharper still images during endoscopic procedures. And it uses 3 CCD technology, the proven standard in today’s OR. Because the camera head can be mounted to the proximal end of any telescope, every specialty benefits of our Image1 HD solution.
The launch of Image 1HD marks a significant improvement over standard definition (SD) and even over early low-end HD video technologies. Image 1has traditionally offered resolution of 720 x 480 (horizontal x vertical) pixels in a 4:3 format and interlaced scanning, represented by the lightest colored frame in the image in the sidebar to the right. Our new FULL HD technology offers images with are solution of 1920 x 1080 an amazing 2 million pixels in a 16:9 format, which is represented by the dark blue frame. Compared with our SD systems, Image 1HD with1080 resolution and progressive scanning provides six times more pixel resolution twice as often to give 12 times more information in each second of video you see.
Image 1 Camera Heads:
Storz SPIES Ref: TC 200
An endoscopic camera system should be as multifaceted as the surgeries performed with it. Like a construction set, the IMAGE 1 SPIES can be adapted to the respective demands to offer users a system that is optimally tailored to their specific needs. In addition, its modular design provides compatibility with future units as well as backward compatibility with nearly all existing 3-chip IMAGE 1 FULL HD camera heads. Many of the existing video scopes can also be integrated via an adaptor.
The 3-chip FULL HD SPIES™ camera heads and video endoscopes for IMAGE 1 SPIES make the functionalities of SPIES available to users. Razor-sharp FULL HD images offer excellent visualization in brilliant quality for optimal medical imaging.
Stryker 1588 AIM Ref: 1588-010-000
Features:
Advanced imaging
Specifications:
Video Outputs
Stryker 1588 AIM Camera Heads:
Stryker 1488HD, 3CCD Digital HD Ref: 1488-010-000
The 1488 HD Camera System is a cross-specialty solution designed to maximize the value of our customers’ investment in Stryker. By designing both hardware and software of the products, Stryker enables better overall performance and functionality of the system through tighter integration of each component in the platform. Because of this integration, Stryker continues to advance the capabilities of the entire portfolio of Stryker products. Beyond just a video platform, Stryker provides a comprehensive cross-specialty surgical solution for customers.
Features & Benefits:
Safety—Patients & Caregivers
Service—Surgeon & Staff Engagement
Sustainability—Operational, Financial, Environmental
Specifications:
Outputs
Additional
Stryker 1488HD Camera Heads:
Stryker Endoscopy 1288 HD Ref: 1288-010-000
The Stryker Endoscopy 1288 HD Medical Video Camera is a high-definition camera used to capture still and video images of endoscopic surgical applications. The 1288 HD Medical Video Camera consists of three main components: Component Camera, console, Camera head, C-mount coupler. The 1288 HD also comes with various connection cables which, like the other components, can be purchased together or separately.
The Camera Console or Camera Control Unit (CCU) is the control center for the 1288 HD Medical Video Camera and processes the video and photographic images captured during the surgical procedure. The console front panel features a touch screen, where different menus can be accessed, including the controls for adjusting the enhancement level, light level, zoom, and white balance, as well as allows the selection of surgical specialty settings that optimize camera performance for various, specific surgical procedures. The front panel also allows activation of remote outputs. The rear panel provides ports for connecting the1288 HD Camera to viewing and recording equipment, such as video monitors, the SDC Ultra, or photo printers.
The camera head connects to the camera console and captures video and photographic images, which it relays to the camera console. It features several controls that are accessible through a button keypad located on the top of the camera head.
The C-Mount coupler threads onto the face of the camera head, enabling a scope to be attached to the camera. It provides a focusing ring to adjust image sharpness.
Technical Specifications
Video Outputs
Mounting Endoscope eyepiece used with C-mount coupler C-mount camera head used with C-mount scopes. (C-mount coupler/scope thread: 1-32" UN 2A)
Auto Shutter Range: 1/60 (1/50) – 1/50,000 second
Operating Conditions: Temperature: 5 – 40°C Relative Humidity: 30 – 95%
Transport and Storage: Temperature: -10 – 60°C
Conditions Relative Humidity: 10 – 75% Atmospheric Pressure: 700 – 1060 hPa
Input Electrical Ratings: 100 – 240VAC ± 10% (0.6A) @ 47 – 63Hz
Total Shipping Weight:
Dimensions:
Stryker 1288HD Camera Heads:
Stryker 1188HD, 3CCD Digital HD Ref: 1188-010-000
Stryker continues to pioneer advancements in minimally invasive surgery with the introduction of its 2nd generation high-definition camera, the 1188 HD 3-Chip Camera. This innovative camera offers outstanding picture quality, enhanced clarity and more intuitive user controls.
Stryker 1188HD Camera Heads:
Features & Benefits
The 1188 HD 3-Chip Camera has been designed to offer the following features and benefits:
Specifications:
Video Outputs
Specifications
Sterilization Steris, Sterrad, Gas, Glutaraldehyde, Cidex Plus, Cidex OPA
Operating Parameters
Stryker 1088HD, 3CCD Digital HD Ref: 1088-010-000
The Stryker Endoscopy Model 1088 Medical Video Camera is a high definition camera used to capture still and video images of endoscopic surgical applications.
The 1088 Medical Video Camera consists of three main components:
The 1088 also comes with various cables, which like the other components, can be purchased together or separately.
The Camera Console
The camera console is the control center for the 1088 Medical Video Camera and processes the video and photographic images captured during the surgical procedure. The front console panel features controls for adjusting the enhance, gain, and white balance, and for selecting surgical specialty settings that optimize camera performance for specific surgical procedures. The rear console panel provides ports for connecting the 1088 Camera to viewing and recording equipment, such as video monitors, the SDC HD, or photo printers.
The Camera Head
The camera head connects to the camera console and captures video and photographic images, which it relays to the camera console. It features several controls that are accessible through a button control pad located on the top of the camera head.
The Coupler
The coupler threads on to the face of the camera head, enabling a scope to be attached to the camera. It provides a focusing ring to adjust image sharpness
Technical Specifications:
Video Outputs
Resolution Horizontal: 1100 lines Vertical: 600 lines
Mounting
Auto Shutter Range 1/60 to 1/50,000 second
Gain OFF 0 dB LOW 5 dB MEDIUM 10 dB HIGH 15 dB
Enhancement 16 levels (switchable)
Operating Conditions
Transport & Storage Conditions
Input Electrical Ratings 100-240V ~ 50/60 Hz 0.6A
Total Shipping Weight 11 lbs (5.0 kg)
Dimensions
Stryker 1088HD Camera Heads:
Stryker 988, 3CCD Ref: 988-010-000
The Stryker Endoscopy Model 988 Medical Video Camera is designed for all types of video endoscopy applications. The Model 988 camera, with the proper coupler, can be used with most endoscopes or arthroscopes. Stryker Endoscopy’s line of focusing camera couplers maximizes the surgeon’s television viewing area for various endoscope sizes and applications. The light sensitivity and color reproduction of the Stryker Endoscopy system produces excellent picture quality.
A Stryker Endoscopy Model 988 Medical Video Camera consists of a camera head, a coupler, a camera control unit, and associated cables. These can be purchased together or separately. Stryker Endoscopy considers instructional training, or in-service, as an integral part of the Model 988 Medical Video Camera. Your local Stryker Endoscopy sales representative will perform at least one in-service at your convenience to help you set-up your equipment and instruct you and your staff on its operation and maintenance. Please contact your local Stryker Endoscopy representative to schedule an in-service after your equipment has arrived.
Imaging System 1/3” Interline Transfer, EX view HAD CCD 768 (H) x 494 (V) pixels
Scanning System 2:1 Interlaced Horizontal: 15.734 kHz Vertical: 59.94 Hz
Video Outputs
Resolution
Mounting
Signal to Noise Ratio 72 dB
Minimum Illumination< 1.0 Lux
Auto Shutter Range1/60 to 1/50,000 second
Gain
Operating Temperature 5° to 40°
Transport & Storage
Power Consumption approx. 30 W
Input Voltage Range 100/120 VAC 50/60 Hz
Total Shipping Weight 13 lbs (5.9 kg)
Dimensions
Enhancement Switchable to 8 steps
Classification & Approvals
Conmed Linvatec Ref: IM4000, 3CCD Digital
IM4000 High Definition Camera TRUE HD-1080p 720p, 1080i, 1080p selectable Upgradeable FPGA platform True autoclavability Eye piece, Cartridge, Urology heads available Clearly True High Definition TM Increased resolution and three dimensional perception Reduce Cost of Ownership: Autoclavable camera head Component level design and manufacturing for reduction of service costs ShockFlex prism mounting in camera heads for increased durability.
Specifications:
I.E.C. Equipment Classification: Type BF, Class 1, continuous operation when used with a Type BF Camera Head.
Typical Operating Requirements:
Video Outputs:
Dimensions
Conmed Linvatec IM400 Camera Heads:
S&N Dyonics 560, 3CCD Digital HD Ref: 72200559
Features:
Conmed Linvatec IM3300 Camera Heads:
Specifications:
Signal System:
Scanning System:
Shutter Speeds: 1/60 to 1/10000 seconds
Video Outputs: Composite
ConMed Linvatec Ref: IM3000 EDTV
Features:
Conmed Linvatec IM3300 Camera Heads:
Specifications:
Scanning System:
Shutter Speeds: 1/60 to 1/10000 seconds
Video Outputs: Composite
S&N Dyonics 560, 3CCD Digital HD Ref: 72200559
The digital-broadcast quality 560 Series 3-CCD High Definition Camera System produces pure HD 1080i imaging. It's a complete end-to-end, high definition system that keeps the HD format throughout the entire video chain including optics, camera head, CCU and monitor. And it meets the ATSC broadcast standards for HDTV.
Native HD image data acquired by the 560 H camera is conveyed to the CCU via a high speed digital interface, where the image data is processed and converted into HDTV images, which can then be displayed on HD flat panel monitors.
560P High Definition Camera System
S&N Dyonics Camera Heads:
Arthrex IMAGE 1
Image 1HD offers the highest standard ever for endoscopic imaging 1080p60. It acquires and displays surgical images in 16:9 for the widest and most natural aspect ratio possible. The technology uses progressive scanning at 60 frames per second to capture fast-moving objects and produce sharper still images during endoscopic procedures. And it uses 3 CCD technology, the proven standard in today’s OR. Because the camera head can be mounted to the proximal end of any telescope, every specialty benefits of our Image1 HD solution.
The launch of Image 1HD marks a significant improvement over standard definition (SD) and even over early low-end HD video technologies. Image 1has traditionally offered resolution of 720 x 480 (horizontal x vertical) pixels in a 4:3 format and interlaced scanning, represented by the lightest colored frame in the image in the sidebar to the right. Our new FULL HD technology offers images with are solution of 1920 x 1080 an amazing 2 million pixels in a 16:9 format, which is represented by the dark blue frame. Compared with our SD systems, Image 1HD with1080 resolution and progressive scanning provides six times more pixel resolution twice as often to give 12 times more information in each second of video you see.
Arthrex Image 1 Camera Heads:
Arthrex Synergy Ref: AR-3200T
Features:
Specifications:
Power Requirements:
Arthrex Synergy Camera Heads:
We would love to have you become a part of our growing family of clients & suppliers!