Arthroscopy - Pumps

Arthrex Continuous Wave II AR-6400

Offers technical innovations that maintain precise joint distention with independent adjustment of in-line pressure and flow levels. New digital technology eliminates pulsing inflow and the autoclavable remote has an added flush button feature.

Arthrex Dual Wave AR-6480

System that maintains constant, non-pulsed control of intra-articular rinsing and distention pressure throughout all phases of an arthroscopic surgical procedure. The AR-6480 is intended to provide continuous pulse-free flow that reacts immediately to changes in the intra-articular pressure so that joint distention can be sustained even under high shaver extraction volumes or secondary outflow.

 

Specifications

  • Width 42 cm (16.5 in.)
  • Height 19 cm (7.5 in.)
  • Depth 35.5 cm (14 in.)
  • Weight 12.25 kg (27 lbs.)
  • Maximum flow rate ≥ 1500 ml/minute
  • Pressure 10 – 120 increments of 5.
  • Overpressure control 300 mmHg ± 5
  • Pressure control Continuous pressure checking
  • Protection IP22
  • Main cable 10 A/250 V
  • Connector CEE 7/7
  • Jack IEC 320/C13
  • Power supply 100-240 V, 50/60 Hz, 6.5A
  • Mains fuse T8LA250V (5 x 20 mm)
  • Shaver supply fuse T5AL250VP (5 x 20 mm)
  • Cleaning Surface cleaning with mild detergent Sterilization Surface disinfection with mild disinfectant

Linvatec / Conmed 10K

Simple, high performance, inflow only pump with flow rates up to 2 liters per minute. Immediate response z High flow z Maintains distention under even the most demanding situations z Robust autoclavable remote control

 

Specifications

Maximum set pressure 150 mmHg

Maximum flow rating 2000ml/min

Weight 7 lbs

Height 6.5"(16.5 cm)

Width 7.75"(19.7 cm)

Depth 8"(20.3 cm

Stryker FloSteady Ref: 350-800-001

Pump offers maximum performance and a compact, space-saving design. This ergonomic, user-friendly pump is equipped with a special “turbo” option for high-fluid procedures.

 

Features & Benefits

  • The FloSteady Arthroscopy Pump offers numerous features for optimal performance and ease of use.
  • Steady flow
  • Turbo option
  • Easy to use
  • Portable
  • Long battery charge

 

Specifications:

  • Mains connection cable: 100-240 V AC 2x T3, 15 A, UL-recognized
  • Connection for potential equalization
  • Frequency: 50–60 Hz
  • Max. Power consumption: Mean value:70 VA
  • Peak value: 140 VA
  • Max. current consumption: 100 V: 1.2 A  240 V: 0.6 A
  • Dimensions: Incl. toggle screw, Width x height x depth 145 x 215 x 230 [mm] / 5.71 x 8.46 x 9.06 [inch]
  • Weight: approx. 9 kg / 9.92 lbs
  • Adjustable pressure range: 15-150 mm Hg (Model 150) 15-200 mm Hg (Model 200)
  • Overpressure safeguard: Motor cutout at 250 mm Hg
  • Capacity/output: 0.1 - 3.0 l/min

Stryker FloControl Ref: 350-600-001

The FloControl pump controls both inflow and outflow as well as regulates shaver suction with a variable flow rate. No special cannulas are needed; however, Stryker “high flow” arthroscopic cannulas or the Stryker Inflow/Outflow cannulas are recommended. Tube sets are ergonomic and intuitive to set up. The FloControl arthroscopy pump can also be used as an inflow only pump. This feature is ideal for shorter procedures or cost cutting measures within the OR.

 

Features & Benefits

  • Programmable joint icons change the flow rate and pressure for ideal performance during knee, shoulder and small joint procedures
  • Wash button quickly clears the joint of debris. Length of wash and pressure increase can vary depending upon surgeon preference
  • Fluid conservation feature helps maximize OR efficiency and reduce cost
  • LCD screen display provides easily identifiable digital readout of flow rate, preset and in joint pressure

 

Specifications

  • Power Supply 100–240 V~
  • Mains fuse T 3.5 A/250 V~
  • UL recognized
  • Frequency 50–60 Hz
  • Max. Power Consumption 145 VA
  • Dimensions Width x height x depth 315 x 215 x 450 [mm]
  • Weight 13.1 kg

Arthrex Continuous Wave III AR-6475

The unique in-line pressure-sensing system provides instantaneous adjustments to flow levels based on intraarticular pressure changes, providing ideal joint distention throughout the procedure. Pressure and flow levels can be adjusted independently on the pump or from the sterile field with the autoclavable remote for optimum control of fluid dynamics. Clear joint distention is maintained even with aggressive shaving, aspiration and multiple arthroscopy portals.

 

Specifications

  • Width 14.5 inches (36.5 cm)
  • Height 5.0 inches (12.5 cm)
  • Depth 12 inches (30 cm)
  • Weight 18 pounds (8.2 kg)
  • Maximum Flow rate 1500 ml/minute
  • Pressure 10 – 120 mmHg increments of 5 mmHg.
  • Overpressure control 300 mmHg
  • Pressure control Continuous pressure checking
  • Protection IPX1
  • Main cable 10 A/250 V
  • Connector CEE 7/7
  • Jack IEC 320/C13
  • Power supply 100-240 V, 50/60 Hz, 6.5A
  • Mains Fuse T2.0A 250V
  • Cleaning Surface cleaning with mild detergent sterilization Surface disinfection with mild disinfectant

Dyonics Access 25 Ref: 72200207

The DYONICS 25 Fluid Management System is an easy to use, high-flow pump with consistent performance in all arthroscopic applications.

 

  • No calibration required
  • Simply insert the tubing cassette and select the cannula size
  • Flow rates up to 2.5 lpm
  • Maintains stable pressure in the joint and also maintains clear field of view
  • A variety of tubing options are available, including day tubing, which enables selection of the most cost-effective solution for the facility

 

Specifications

  • Input Power 100–120/200–240 V ± 10%, 50/60 Hz
  • Rated Power Input 300 VA
  • Output Pressure 10 to 150 mmHg
  • Flow Rate High Flow Cannula setting: 0.5 L/min to 2.5 L/min
  • Medium Flow Cannula setting: 0.5 L/min to 1.6 L/min
  • Low Flow Cannula setting: 0.3 L/min to 0.5 L/min
  • Fuses Dual fuses: 4A/250 V
  • Dimensions 5.75" H X 12" W X 14.25" D  (146 mm H X 305 mm W X 362 mm D)
  • Weight 12.4 lb  (5.6 kg)

Linvatec / Conmed 24K

Delivers high performance with custom functions and flexible features that allow you to get the job done, including inflow/outflow control capabilities, true Intra-articular Pressure Sensing (TIPS), and shaver suction control, flow rates up to 2 liters per minute, and an EcoFlow® day-use tubing option that may increase efficiency in a busy OR.

 

Component Features and Benefits:

  • Dual rotors and pinch valve – allows the pump to operate in inflow/outflow/shaver suction mode which provides a complete fluid management solution.
  • Single Rotor Operation – Easy set up to operate with inflow only 10k® tube set for simple diagnostic arthroscopy.
  • Independent pressure, flow and shaver suction controls – Increases the surgeon’s ability to tailor the function of the pump to the surgical requirements.
  • Selectable Wave Mode - Keeps the joint crystal clear even with 2 portal knee arthroscopy.
  • Independent tamponade and flush control – Simplifies controlling bleeding and clearing debris with the Clearfield button.
  • Drain button – A simple and effective method of removing the remaining fluid from the joint.

 

Specifications

  • Max Pressure 150 mmHg  Min Pressure 10 mmHg
  • Weight 10.3 lbs
  • Height 7.1 in  Width 14 in  Depth 15.9 in
  • Max Flow Rate 2500 mL/minute
  • Outflow (L/M/H) 50/150/300 mL/min
  • Suction (L/M/H) 500/850/1200 mL/min
  • Knee Preset 30 mmHg
  • Shoulder 40 mmHg
  • Hip Preset 70 mmHg
  • Small Joint 20 mmHg

Stryker Arthropump

Ref: 350-357-000 Hermes Ready

This device provides fluid distention of articular cavities for diagnostic and / or operative arthroscopic proce­dures.

 

Such procedures may include:

  • Ligament injuries
  • Meniscus injuries
  • Cartilage injuries
  • Operation planning and re-examination

 

Specifications

  • Power Supply 100-240 V- Mains fuse T 5 A
  • Frequency 50-60 Hz
  • Power Consumption Max. Current 75W
  • Dimensions Width x height x depth 360 x 145 x 300 [mm]
  • Weight Approx. 8.5 kg

Stryker CrossFlow  Ref: 450-000-000

Dual arthroscopic pump system intended to provide fluid distension and irrigation of the knee, shoulder, hip, elbow, ankle and wrist joint cavities and fluid suction during diagnostic and operative arthroscopic procedures.

 

Stryker’s CrossFlow Integrated Arthroscopy Pump combines high end performance and resection integration to create one of the most leading edge fluid management systems on the market. CrossFlow is the ideal solution for users seeking simplicity and versatility, while never compromising performance.

 

Specifications

  • Connection Input Voltage: 80–275 V
  • Inlet Fuse: 10 A, 250 V Frequency 47–63 Hz
  • Dimensions Width x height x depth 12.528 x 7.025 x 16.99 (Inch)
  • Weight 24lbs

We would love to have you become a part of our growing family of clients & suppliers!